伍文杰   Associate professor

伍文杰,男,华中科技大学 物理学院副教授,Micromachines 编辑,自然科学基金委函评专家,IOP Trusted Reviewer,IEEE Member,中国微米纳米技术协会高级会员,光电子光子材料与器件学术会议学术委员。近五年作为负责人主持工信部高质量发展专项子课题、国家重点研发计划子课题、自然科学基金面上项目、自然科学基金青年基金、中国博士后特别资助(站中)、中国博士后科学基金等项目,总经费超过700万元。长期从事高端MEMS加速...Detials

A precise spacing-control method in MEMS packaging for capacitive accelerometer applications

Release time:2021-07-08  Hits:

  • Indexed by:Journal paper
  • First Author:WU WENJIE
  • Correspondence Author:HU CHEN YUAN,Fan Ji,Tu Liangcheng
  • Co-author:Liu Dandan,Qiu Wenrui,LIU HUAFENG,Fangjing Hu
  • Journal:Journal of Micromechanics and Microengineering
  • Included Journals:SCI、SSCI
  • Discipline:Engineering
  • First-Level Discipline:Electronic Science And Technology
  • Document Type:J
  • Volume:28
  • Key Words:MEMS packaging, spacing control, sensitivity improvement, 3D electroplating, accelerometer
  • DOI number:10.1088/1361-6439/aae9cd
  • Date of Publication:2018-10-19
  • Abstract:Capacitive micro accelerometers with high sensitivity have found wide applications in geophysics. Reducing the interelectrode spacing, which is determined by the thickness difference between the electrodes and the solder bumps in flip-chip utectic bonding, is an efficient way to improve the sensitivity of area-varying capacitive transducers in micro accelerometers. raditional methods require extra materials and processes, and precise control of the thickness of both the solder pumps and the electrodes is necessary. This work introduces a novel method for the precise control of the interelectrode spacing using a three dimensional (3D) electroplating process. Standoff pillars and electrodes are deposited by a single electroplating process with a constant thickness difference, which is only determined by the gap of the seed features that can be precisely determined by photolithography. The standoff pillars are used to define the thickness of the solder bumps in the packaging process. The 3D electroplating process is studied, characterized and applied to a typical high-precision micro capacitive area-varying accelerometer. Experimental results show that the variation of the interelectrode spacing is decreased by more than 6.5 times, when compared to that without the 3D electroplating process. Benefitting from the reduced interelectrode spacing, the ensitivity is increased by more than 3 times, while the resolution is 10 ng (√Hz)−1, which is 2.5 times better. It is believed that such a method can be applied to MEMS devices where interelectrode spacing needs to be precisely controlled.